| Allgemeine Information | acA5472-5gc | |
|---|---|---|
| Artikelnummer | 107770 | |
| Produktlinie | ace U | |
| Sensor | ||
| Sensorhersteller | Sony | |
| Sensor | IMX183 | |
| Shutter-Technologie | Rolling Shutter | |
| Sensorformat | 1 | |
| Sensortypen | CMOS | |
| Sensorgröße | 13,1 mm x 8,8 mm | |
| Auflösung (HxV) | 5472 px x 3648 px | |
| Auflösung | 20 MP | |
| Pixelgröße (H x V) | 2,4 µm x 2,4 µm | |
| Bildrate | 5 fps | |
| Mono/Farbe | Color | |
| Kameradaten | ||
| Schnittstelle | GigE | |
| Pixel Bit Depth | 10/12 bits bits | |
| Synchronisierung | free-run | |
| hardware trigger | ||
| software trigger | ||
| Belichtungssteuerung | programmable via the camera API | |
| hardware trigger | ||
| Digitaler Input | 1 | |
| Digitaler Output | 1 | |
| General Purpose I/O | 1 | |
| Stromversorgung | PoE or 12-24 VDC | |
| Leistung (typisch) | 2,8 W | |
| Leistung PoE | 3,1 W | |
| Bauform | ||
| Housing Typ | Box | |
| Größe (L x B x H) | 42 mm x 29 mm x 29 mm | |
| Objektivanschluss | C-mount | |
| Betriebstemperatur | 0 – 50°C | |
| Gewicht (typisch) | 90g | |
| Konformität | ||
| Konformität | RoHS | |
| GigE Vision | ||
| FCC Class B | ||
| CE | ||
| GenICam | ||
| UL | ||
| KC | ||
| EAC |
| Features | acA5472-5gc |
|---|---|
| Chunks | CRC Checksum |
| Exposure Time | |
| Frame Counter | |
| Gain | |
| Gain All | |
| Line Status All | |
| Sequence Set Index | |
| Timestamp | |
| Trigger Input Counter | |
| Color Creation and Enhancement | Balance White (Manual White Balance) |
| Balance White Auto (Automatic White Balance) | |
| Color Adjustment (6-axis Hue/Saturation) | |
| Color Transformation | |
| Hue and Saturation | |
| Event Reporting | Acquisition Start |
| Acquisition Start Overtrigger | |
| Acquisition Start Wait | |
| Action Late | |
| Critical Temperature | |
| Event Overrun | |
| Exposure End | |
| Frame Start Overtrigger | |
| Frame Start Wait | |
| Over Temperature | |
| GigE Vision 2.0 | Action Commands (Synchronous Triggering) |
| Precision Time Protocol (IEEE 1588) | |
| Scheduled Action Commands | |
| Synchronous Free Run | |
| I/O Control | Debouncer |
| Line Minimum Output Pulse Width | |
| Image Acquisition Control | Acquisition Frame Rate |
| Acquisition Mode | |
| Acquisition Start Trigger | |
| Acquisition Start, Stop, and Abort | |
| Acquisition Status | |
| Frame Start Trigger | |
| Sensor Readout Time | |
| Sensor Shutter Mode | |
| Trigger Delay | |
| Triggered by Hardware | |
| Triggered by Software | |
| Light Control Features | Basler SLP |
| Line Source Signals | Exposure Active |
| Flash Window | |
| Frame Trigger Wait | |
| Timer 1 Active | |
| Miscellaneous | Device Information Parameters |
| Remove Parameter Limits | |
| User Sets (Configuration Sets) | |
| User-Defined Values | |
| Vignetting Correction | |
| PGI | 5×5 Debayering |
| Color-Anti-Aliasing | |
| Denoising | |
| Improved Sharpness | |
| Pixel Formats | Bayer RG 12 |
| Bayer RG 12 Packed | |
| Bayer RG 8 | |
| Mono 8 | |
| YUV 4:2:2 (YUYV) Packed | |
| YUV 4:2:2 Packed | |
| Standard Features | Auto Function Profile |
| Black Level | |
| Center X and Center Y | |
| Counter | |
| Digital Shift | |
| Exposure Auto | |
| Exposure Mode: Timed | |
| Exposure Time | |
| Gain | |
| Gain Auto | |
| Gamma Correction | |
| Image ROI (Region of Interest) | |
| Lookup Table (LUT) | |
| Reverse X (Horizontal Mirroring) | |
| Reverse Y (Vertical Mirroring) | |
| Sequencer (GigE Cameras) | |
| Test Images | |
| Timer |